DIESEL LOCO - Power Ground
Earth fault occur in power circuit is called power ground.
When earth faults in traction motor, traction motor cables, BKT, REV, power contactors, GR1 operates with indications. Check following items -
1. Traction motor cables are tightened properly.
2. If there are any metal or wire pieces in between BKT/Rev./Power contactors, remove it.
3. Check the wire connection of load meter.
4. If there is smell or smoke from any TM, isolate it.
Note
- If power ground comes on higher notches, work on lower notches.
- TM 4, 5, 6 can be isolate through MCO, if additional contactors (AC1, AC2, AC3) are provided on back panel, then TM 1, 2, 3 can be isolated through MCO in case of power ground.
- When GR1 operate during dynamic braking don’t use DB.
- Loco is provided with GR1 and GR2 and during engine starting, if GR2 operates. In this condition first start the engine, then reset it.
- One GR is provided in WDM-2 loco. At the time of engine starting, if GR operates. In this condition first start the engine, then reset it and note down in the repair book.
----------------
Wheel Slip
The process of wheel slipping is called wheel slip. When the difference of current occurs between two traction motors then related WSR will energize with the following indications –
1. Wheel slip lamp will glow.
2. Buzzer sounds.
3. Automatic sanding takes place.
4. Load meter fluctuates.
Momentary Wheel Slip - Momentary wheel slip occurs whenever there is oily and wet track, during transition, while opening notches quickly. To avoid this reduce the notch and apply sanders.
Motor Cut out Switch It is a rotating type switch provided on front panel. It is used to isolate the TM. It has 7 positions.
How to Operate MCO
1. MH should be kept to idle position
2. Break the MCO seal.
3. Rotate the MCO from All IN position to CO1, CO2, CO3, CO4, CO5, CO6 position.
After Isolating TM By MCO:
1. Series power contactor will not pick up.
2. Only five parallel power contactors will pick up.
3. Transition will not come.
4. Dynamic brake isolated.
5. Load meter will not showing current, if TM-1 is isolated.
Load Meter